[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [Rollei] TLR Meter
- Subject: Re: [Rollei] TLR Meter
- From: Marc James Small <msmall >
- Date: Thu, 24 Apr 2003 21:25:31 -0400
- References: <5C7752CCB00C3A47A70D5C4204A360B255497F >
At 09:26 PM 4/23/03 -0700, Richard Knoppow wrote:
> I think all Rollei meters are Selenium cell types. If the
>cell goes bad there is no way to compensate it because the
>error varies with light level. The usual symptom is that it
>reads low at the high end of the scale. The only fix is
>replacing the cell.
Thanks, Richard, for a most illuminating post. 2.8GX and FX meters, of
course, are not selenium.
Marc
msmall FAX: +276/343-7315
Cha robh bàs fir gun ghràs fir!
------------------------------