There is a switch located atop the camera to one side. If red shows (black
is for regular/normal light conditions) it is for lower ambient light
conditions. you then use the EV numbers in the red frame on the meter (left
side of camera) to set your EV setting dials. Hope this helps.
- -----Original Message-----
From: Craig Roberts [mailto:crgrbrts ]
Sent: Tuesday, April 02, 2002 2:52 PM
To: rollei us
Subject: [Rollei] 2.8E meter repair questions
Good evening gurus,
I have a couple of questions about the meter on my newly acquired 2.8E.
1) It appears to be a "dual range" meter. How does one change ranges from
low to high light sensitivity?
2) How is the ASA dial set? Do you really have to rotate the meter knob
beyond the stops?
3) How does one service or remove the meter housing? Mine is physically
loose on the focusing knob, but I see no way to access the assembly.
Finally,
4) If I want to remove the selenium cell and galvanometer from the camera,
are the factory stock "blanks" as installed in non-metered models generally
available?
Thanks very much,
Craig
near Washington, DC
- ------_=_NextPart_001_01C1DAA2.1E047410
Content-Type: text/html;
charset="iso-8859-1"
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
<HTML><HEAD>
<META HTTP-EQUIV="Content-Type" CONTENT="text/html; charset=iso-8859-1">
<TITLE></TITLE>
<META content="MSHTML 5.50.4807.2300" name=GENERATOR>
<STYLE></STYLE>
</HEAD>
<BODY bgColor=#ffffff>
<DIV><SPAN class=417550400-03042002><FONT face=Arial color=#0000ff>There is a
switch located atop the camera to one side. If red shows (black is for
regular/normal light conditions) it is for lower ambient light conditions.
you then use the EV numbers in the red frame on the meter (left side of camera)
to set your EV setting dials. Hope this helps.</FONT></SPAN></DIV>
<BLOCKQUOTE dir=ltr
style="PADDING-LEFT: 5px; MARGIN-LEFT: 5px; BORDER-LEFT: #0000ff 2px solid; MARGIN-RIGHT: 0px">
<DIV class=OutlookMessageHeader dir=ltr align=left><FONT
face=Tahoma>-----Original Message-----<BR><B>From:</B> Craig Roberts
[mailto:crgrbrts ]<BR><B>Sent:</B> Tuesday, April 02, 2002 2:52
PM<BR><B>To:</B> rollei
meter repair questions<BR><BR></FONT></DIV>
<DIV><FONT face=Arial>Good evening gurus,</FONT></DIV>
<DIV><FONT face=Arial></FONT> </DIV>
<DIV><FONT face=Arial>I have a couple of questions about the meter on my newly
acquired 2.8E. </FONT></DIV>
<DIV><FONT face=Arial></FONT> </DIV>
<DIV><FONT face=Arial>1) It appears to be a "dual range" meter. How does one
change ranges from low to high light sensitivity?</FONT></DIV>
<DIV><FONT face=Arial></FONT> </DIV>
<DIV><FONT face=Arial>2) How is the ASA dial set? Do you really
have to rotate the meter knob beyond the stops? </FONT></DIV>
<DIV> </DIV>
<DIV><FONT face=Arial>3) How does one service or remove the meter housing?
Mine is physically loose on the focusing knob, but I see no way to access the
assembly.</FONT></DIV>
<DIV> </DIV>
<DIV><FONT face=Arial>Finally,</FONT></DIV>
<DIV> </DIV>
<DIV><FONT face=Arial>4) If I want to remove the selenium cell and
galvanometer from the camera, are the factory stock "blanks" as installed in
non-metered models generally available?</FONT></DIV>
<DIV><FONT face=Arial></FONT> </DIV>
<DIV><FONT face=Arial>Thanks very much,</FONT></DIV>
<DIV><FONT face=Arial></FONT> </DIV>
<DIV><FONT face=Arial>Craig</FONT></DIV>
<DIV><FONT face=Arial>near Washington, DC</FONT></DIV>
<DIV> </DIV></BLOCKQUOTE></BODY></HTML>
- ------_=_NextPart_001_01C1DAA2.1E047410--
------------------------------